When installing the booster pump, be sure to install it horizontally or vertically in the “Installation Mode” display. The water flow direction should be consistent with the direction of the arrow on the pump body, and it should be installed at the lowest position away from the water level as much as possible. To facilitate use and maintenance, a valve should be installed on the pump inlet pipeline.
1. When the pumped liquid level is lower than the upper end surface of the pump impeller or the pump shaft, the pump should be equipped with a check valve, and the outlet end should be connected to a tee for water diversion. When in use, the pump should be filled with water and the Tighten the screw plug. The pipeline connections should be tight, especially the water inlet pipeline should not leak, otherwise the pump lift will be reduced or water will not be pumped. Before water enters the pump chamber, do not rotate continuously for a long time to avoid damaging the mechanical seal.
2. The motor coil is equipped with a safety protector. When the pump fails or the water cannot be pumped, causing the motor temperature to rise above the specified value, the circuit can be automatically cut off. After the fault is eliminated, the motor temperature rise drops and the operation can be automatically resumed. The booster pump motor is a capacitor-operated motor, and the rotation direction has been adjusted when the pump leaves the factory. If you need to replace the capacitor or rewiring, please wire according to the arrow direction mark on the pump body. To ensure safe use, please use a three-core safety socket with a ground wire.
3. When water leakage is found in the pump, stop it immediately and check to prevent internal leakage. If water leaks from the connection part with the motor, replace the mechanical seal. Check if the power is on. Check whether the power supply voltage used is consistent with the working voltage of the pump. Open the pump cover, remove foreign matter in the pump, reinstall the pump cover, and tighten it to normal.
For the installation parts of the water pipe booster pump, everyone needs to know the specific installation method and the installation method, so as to ensure that the family can use water normally. The above is the relevant introduction about the methods of boosting water pipes without electricity and the installation methods of water pipe booster pumps. When installing the water pipe booster pump, you must understand the method of boosting.